產(chǎn)品介紹 當(dāng)前位置:首頁 > 產(chǎn)品介紹 > 無創(chuàng)血壓系統(tǒng)

類型: 無創(chuàng)血壓系統(tǒng)

名稱:多通道血壓分析系統(tǒng)

Multi Channel Blood Pressure Analysis System

型號(hào):MC4000

  • 產(chǎn)品介紹
  • 產(chǎn)品特點(diǎn)
  • 產(chǎn)品參數(shù)
  • 產(chǎn)品應(yīng)用
  • 文獻(xiàn)參考

MC4000多通道血壓分析系統(tǒng)是一種非侵入性的儀器,旨在幫助研究人員有效地獲得精確測量的大小鼠的血壓。動(dòng)物平臺(tái):動(dòng)物平臺(tái)包括獲取血壓結(jié)果的尾套和傳感器組件。在測試期間,尾套逐漸膨脹包圍尾巴,使動(dòng)物不會(huì)驚動(dòng)到而停止血流量。平臺(tái)通電時(shí),真空熒光顯示屏位于動(dòng)物平臺(tái)前方,不間斷地監(jiān)控每個(gè)通道的溫度水平。傳感器組件包括一個(gè)自定義的“V型切口”的設(shè)計(jì),用來固定動(dòng)物的尾巴。傳感器的頂部是便于拆卸的磁性裝置,便于安置動(dòng)物和快速安全的固定尾巴。這兩個(gè)特點(diǎn),大大減少了尾巴的運(yùn)動(dòng),從而得到最好的結(jié)果。此外,尾套和傳感器組件不需要因?yàn)閯?dòng)物的大小而更改,一套組件將適合所有的小鼠或大鼠的尺寸。

 

MC4000組件:
1 動(dòng)物平臺(tái):大鼠或小鼠
2 動(dòng)物固定器:小鼠和大鼠
3 動(dòng)物盤
4 電源/實(shí)用工具
5 MC4000軟件

 

系統(tǒng)軟件: 
MC4000是一個(gè)自定義分析軟件,目的是獲取、整理并研究大量的大小鼠血壓測量數(shù)據(jù)。測量收縮壓、舒張壓、脈率和平均動(dòng)脈壓 ,自動(dòng)計(jì)算結(jié)果的平均值和標(biāo)準(zhǔn)偏差,并實(shí)時(shí)顯示多個(gè)波形 。可保存所有的測量、波形和統(tǒng)計(jì)。

 

雙平臺(tái)操作:
MC4000雙平臺(tái)操作允許一個(gè)用戶操作多達(dá)八個(gè)動(dòng)物。通過添加第二個(gè)同種的平臺(tái),MC4000可以輸出雙倍的結(jié)果。或增加不同的平臺(tái),使一個(gè)系統(tǒng)可以同時(shí)獲取小鼠和大鼠的血壓結(jié)果。

 

 

1    小鼠血壓和大鼠血壓尾套系統(tǒng)
2    四到八個(gè)通道
3    電腦控制,軟件操作
4    易于組裝、清潔和保養(yǎng)
5    測量結(jié)果包含:收縮壓、舒張壓、平均動(dòng)脈壓和脈率 
6    實(shí)時(shí)波形顯示測量 
7    獨(dú)特的“V型切口”傳感器組件 
8    嚙齒類動(dòng)物固定器確保安全的固定未受過訓(xùn)練的動(dòng)物 
9    特別的設(shè)計(jì),以減少固定動(dòng)物的壓力
10  收縮壓和舒張壓被測量,而不是計(jì)算 
11  在15分鐘內(nèi)獲得小鼠或大鼠的15次測量

1    小鼠血壓和大鼠血壓尾套系統(tǒng)
2    四到八個(gè)通道
3    電腦控制,軟件操作
4    易于組裝、清潔和保養(yǎng)
5    測量結(jié)果包含:收縮壓、舒張壓、平均動(dòng)脈壓和脈率
6    實(shí)時(shí)波形顯示測量
7    獨(dú)特的“V型切口”傳感器組件
8    嚙齒類動(dòng)物固定器確保安全的固定未受過訓(xùn)練的動(dòng)物
9    特別的設(shè)計(jì),以減少固定動(dòng)物的壓力
10  收縮壓和舒張壓被測量,而不是計(jì)算
11  在15分鐘內(nèi)獲得小鼠或大鼠的15次測量

 

Mc4000多通道血壓分析系統(tǒng)是一種非侵入性的儀器,旨在幫助研究人員有效地獲得精確測量的大小鼠的血壓。

Multiple FeatureExtraction Based on PPG Signal to Realize Blood Pressure Measurement ofComposite Multi-channel Convolutional Neural Network Model

Cheng-GangLuL.Wang

Computer Science

IEEE 3rd International Conference on Electronic…14 April2023

The overall blood pressure valueis evaluated using a "compound multi-channel convolutional neural network(CMCNN)" model andconsidering that the distorted data caused by motion artifacts causes thetraining results to fail to converge, the results is closer to the actualsituation. 


Effect of Jouleheating and entropy generation on multi-slipcondition of peristaltic flow of Casson nanofluid in an asymmetric channel

AshaS. KotnurkarN.Kallolikar

Physics

Journal of biological physics (Print)   28 April 2022

In the present investigation, the effect of multi-slip condition on peristaltic flow throughasymmetric channel with Joule heating effect is considered. We alsoconsidered the incompressible Expand


Home Blood Pressure Control and Drug Prescription Patterns among ThaiHypertensives: A 1-Year Analysis of Telehealth Assisted Instrument in Home Blood Pressure MonitoringNationwide Pilot Project

A.SakulsupsiriP.Chattranukulchai+15 authors S.Sangwatanaroj

Medicine   International Journal of Hypertension  14 April 2021

With the implementation of HBP telemonitoring, the BPcontrol rate based on HBP analysis was still low, and the long-term clinical benefit ofovercoming therapeutic inertia alongside HBPtelemonitoring needs to bevalidated in a future study.Expand


Sensitivity andVariance Analysis of Arterial Pressure Transfer Dynamics Estimated from Adaptive Multi-Channel System Identification

J.HahnA.ReisnerH.Asada

Engineering  American Control Conference   9 July 2007

This paper analyzes the parametric sensitivity andasymptotic variance of the arterial pressure transfer dynamics estimated from the adaptive multi-channel (AMC) system identificationtechnique Expand


BESN System of Multi-channel Tail-artery Blood Pressure Measurement

 Medicine   2004  The new method of blood-pressure measurementwas accurate and reliable and the data of BP and HR obtained by the BESN system werealmost identical when compared with direct operation on anaesthetized rats.Expand


Single pillregimen improves persistence and leads lo better clinical outcome compared toidentical multi pillcombination. Results of START, a German claims data analysis

H.PredelB.Weisser+7 authors M.Boehm

Medicine  1November 2020

The results of the START study strongly support the useof a SP concept in the AH medication treatment as recommended by the currentESH/ESC-Guidelines for the treatment of AH.


Development ofan intelligent bedsore prevention system based on multi-channel pressure signals analysis

XiaoxiaHaoRunjingZhou

Computer Science

International Symposium on Instrumentation and…10 October2008

An intelligent pressure analysis system was designed based on the improved bedsore preventionmattress. The system can recognize the area of the human body that need to bemassaged according to the… 

 

A NovelMicrochip Flow Chamber (Total Thrombus Analysis System) to Assess Canine Hemostasis

T.IwanagaN.MiuraB.BrainardM.BrooksR.Goggs

Medicine

Frontiers in Veterinary Science  2 June 2020

Initial evaluations of the T-TAS suggest it may aidcharacterization of hemostasis in patients at-risk of bleeding and assist withdelineating bleeding phenotypes.


Multi-channel Pulse Acquisition System Based on STC89C52

FengFan  Physics 2011

Pulse is a common physiological phenomenon in clinicalexaminations and physiological study.The wave amplitude and form of pulsecontains the important physiological information which reflects the… 


Multi-MorphologicalPulse Signal Feature Point Recognition Based on One-Dimensional DeepConvolutional Neural Network

GuotaiWangXingguangGeng+4 authors HaiyingZhang

Computer Science Inf.  26 January 2023

The multi-classpulse signal characteristic parameter recognition model based on theone-dimensional deep convolutional neural network (1D-DCNN) model canefficiently and accurately identify pulse time-domain characteristicparameters, which can be applied to discriminate time- domain pulse informationin clinical practice and assist doctors in diagnosis.Expand